The best directly-reported values for cytoplasmic (cytosolic) viscosity come from evanescent field frequency-domain microfluorimetry in living cells: 1.1 Β± 0.2 cP in Swiss 3T3 fibroblasts and 1.0 Β± 0.2 cP in MDCK cells, measured with BCECF (fluorescence lifetime 3.7 Β± 0.1 ns) in a layer extending from the plasma membrane into bulk cytoplasm; the authors conclude cytoplasmic fluid-phase viscosity is close to that of water (~0.89 cP at 37 Β°C).
For calibration context, pure water at room temperature is ~1 cP (dielectric constant 80.1), while common calibration solvents for viscosity probes span glycerol 945 cP, ethylene glycol 13.5 cP, DMSO 2.47 cP, and ethanol 1.2 cP.
"Cytosol" viscosity is specific to the aqueous fluid phase. Mitochondrial micro-viscosity is roughly 60-fold higher (~62 cP, rising to ~110 cP after nystatin) in HeLa cells per a ratiometric coumarin-BODIPY sensor with FLIM validation. Do not confuse cytosolic values with blood/plasma viscosity, which depends on hematocrit (r = 0.753) and fibrinogen (r = 0.49) in humans.
Uncertainty and confidence: The 1.0β1.1 cP figure comes from a single well-reproducible technique in two mammalian cell lines (high confidence for fluid-phase cytoplasm near the membrane region); values may shift with cell state, crowding, and subcellular location, and the supplied evidence does not cover other cell types or conditions such as stress or apoptosis.