"The scientific man does not aim at an immediate result. He does not expect that his advanced ideas will be readily taken up. His work is like that of the planter - for the future. His duty is to lay the foundation for those who are to come, and point the way."
Main claim MHCquant2 is an open-source nf-core Nextflow pipeline that increases sensitivity for HLA class I and II peptide identification by integrating peptide property predictors (DeepLC and MS2PIP) with OpenMS and Percolator, expands benign immunopeptidome references, and refines tumor-associated antigen and neoepitope discovery
Bottom line The pipeline is a robust, reproducible, and community-ready tool that meaningfully increases identifications (esp low-abundance peptides) and provides a larger benign reference for safer tumor antigen selection, but experimental and clinical validation of novel TAAs/neoepitopes remains needed
MHCquant2 is presented as an nf-core Nextflow pipeline that (1) integrates retention time and fragment intensity predictors (DeepLC, MS2PIP via MS2Rescore), (2) rescoring with Percolator and OpenMS quantification modules, (3) provides timsTOF support and scalable parallelization, and (4) when applied to a novel benign dataset (n=92) and combined with public data, expands the benign immunopeptidome by >160,000 unique peptides and improves identification rates for low-abundance peptides β claims supported by deposited data and reproducible code availability
What the authors did (methods snapshot)
Built MHCquant2 as nf-core/Nextflow DSL2 pipeline using OpenMS tools, Comet search engine, Percolator rescoring, MS2Rescore to call DeepLC and MS2PIP, and OpenMS FeatureFinder quantification modules; code and containers provided for reproducibility
Generated a novel benign timsTOF dataset: 92 primary benign tissue samples spanning 23 tissues, analyzed with timsTOF PASEF and processed with MHCquant2; raw data deposited to PRIDE (PXD058436) and pipeline on GitHub/Zenodo for versioned reproducibility
Benchmarked against FragPipe and PEAKS and re-analyzed published tumor datasets (AML, CLL, OvCa, melanoma) to evaluate tumor antigen discovery and benign overlap.
Key results (data highlights)
MHCquant2 increased unique HLA class I binder identifications to 133,163 (13.2% higher vs FragPipe; 2.8% vs PEAKS) and HLA class II peptides to 204,291 (5.1% vs FragPipe) on the benign dataset; mean allotype improvements observed across HLA class I alleles
MHCquant2-exclusive identifications biased to lower intensity: median intensity of pipeline-exclusive class I and II binders was 3.4-fold and 2.1-fold lower than shared peptides β indicating improved sensitivity to low-abundance peptides
Expanded benign reference: combining reanalyses and the novel dataset produced a benign reference of 420 HLA class I samples (213,462 unique binders) and 415 HLA class II samples (423,438 unique peptides), adding >160,000 new identifications overall; this impacted published tumor antigen lists where substantial fractions of putative TAAs were found in the expanded benign set and therefore excluded
Re-analysis of prior tumor TAA sets: for AML 40.2% of published class I TAAs were excluded by the extended benign reference; CLL TAAs expanded heavily with 69.9% MHCquant2-exclusive TAAs; OvCa TAAs also changed β demonstrating that analysis pipeline and benign references materially alter candidate TAA lists
Neoepitope sensitivity: MHCquant2 identified additional low-abundance neoepitopes in a melanoma dataset (six additional neoepitopes with four validated by synthetic peptide spectral comparison) improving confidence in mutationβderived peptides presentation
Strengths
Open, reproducible, containerized, nf-core implementation enabling portability and community contributions; code, containers, and data are available (GitHub, nfβcore page, Zenodo, PRIDE)
Quantitative benchmark vs two state-of-the-art pipelines across a sizable, timsTOF-derived benign dataset (n=92), demonstrating measurable gains including improved low-abundance sensitivity.
Careful per-run Percolator feature weight analysis showing additive contributions of DeepLC and MS2PIP to rescoring, adding mechanistic interpretability to the sensitivity gains.
Limitations, caveats, and potential biases
Benign reference representativeness. The benign set increases coverage but is still limited by tissue sourcing (postβmortem samples from specific centers and selected tissues); some tissue types or physiological states may remain under-sampled, which can bias exclusion of TAAs if benign sampling is incomplete
FDR and false positives. Increased identifications remain within 1% peptideβlevel FDR by Percolator, but rescoring and feature augmentation can shift score distributions β independent orthogonal validations (targeted MS, T cell reactivity, or synthetic peptide spectral matches) are required to confirm biological presentation and immunogenicity beyond spectral confidence; the authors provided some synthetic validations but largeβscale orthogonal biological validation remains pending
Platform and model generalizability. DeepLC and MS2PIP models may not be equally trained for every instrument or fragmentation regime; while authors used timsTOF-specific MS2PIP models and benchmarked across platforms, some biases (length/hydrophobicity) in pipeline-exclusive sets versus other tools suggest model-dependent effects that may not generalize universally
Downstream clinical significance. Removing candidate TAAs because they are seen in an expanded benign set is appropriate as a conservative safety step, but absence from benign data is necessary but not sufficient for clinical target suitability β functional immunogenicity, expression localization, and onβtarget toxicity need independent evaluation.
Practical recommendations for users
Use MHCquant2 for reproducible highβthroughput reanalysis and when sensitive detection of lowβabundance peptides is desired; leverage the nfβcore profile and container images to keep environments consistent
When generating clinical candidate lists, always crossβvalidate MHCquant2 calls with orthogonal assays: synthetic peptide spectra, targeted PRM/SRM, and functional T cell assays; consider tissue expression and singleβcell data to rule out low-level healthy expression not captured by benign samples.
Be mindful of prediction model versions: update MS2PIP/DeepLC models for instrument type and retrain if possible for new fragmentation schemes; inspect length/hydrophobicity distributions of pipeline-exclusive peptides as sanity checks.
Open questions and next experiments
Systematic orthogonal validation: design a tiered validation study across tissues and tumors where MHCquant2-exclusive TAAs/neoepitopes are tested by synthetic spectra, targeted MS, and T cell activation assays to quantify true positive rate and immunogenic relevance.
Model robustness: retrain or fine-tune DeepLC and MS2PIP on instrument- and sample-specific immunopeptidomics data (including timsTOF and other ion mobility instruments) and measure identification shifts; this will clarify which gains are model-driven versus pipeline integration-driven.
Population representation: expand benign sampling to additional tissues, age groups, ethnicities, and inflammatory states to ensure the benign reference reduces false negatives for clinically relevant TAAs.
Conclusions and confidence
Evidence supports that MHCquant2 is a meaningful, reproducible improvement to immunopeptidomics workflows: it yields measurable increases in identifications (notably lowβabundance peptides), provides a large, shareable benign reference, and materially changes candidate TAA lists from previous studies. The results are well supported by deposited data and open code; however, translation to clinical antigen selection requires orthogonal biological validation and attention to benign reference representativeness
Integrates state-of-the-art peptide property predictors into a portable nf-core pipeline and demonstrates measurable identification gains and benign reference expansion; novelty lies in combining reproducible engineering, instrument-specific optimizations, and large benign dataset application.
Scientific Quality
90%
High technical rigor, open code and data deposition, clear benchmarking versus competing pipelines, and mechanistic feature weight analyses; limitations relate to generalizability and need for broader orthogonal biological validation rather than computational execution.
Study Generality
90%
Pipeline design and principles are broadly applicable across immunopeptidomics projects and instruments (timsTOF and others), and the expanded benign reference will be widely useful for antigen discovery workflows.
Study Usefulness
90%
Provides an immediately usable, reproducible tool that increases sensitivity for low-abundance peptides and a larger benign reference to reduce false positive TAAs; directly actionable for labs performing immunopeptidomics.
Study Reproducibility
90%
High β nf-core Nextflow implementation, containerization, Zenodo/GitHub releases, and PRIDE data deposition (PXD058436) permit reproduction; some dependence on model versions (DeepLC/MS2PIP) requires careful version control.
Explanatory Depth
80%
Authors provide per-feature Percolator analyses and link sensitivity gains mechanistically to predictors and rescoring; however, biological mechanistic validation (T cell assays) of candidate antigens is limited.
Preparing reproducible benchmark analysis code to compare MHCquant2, FragPipe, and PEAKS identification sets using PXD058436, plotting overlap, length, and intensity distributions to reproduce paper figures.
Get emailed when your analysis is done!
We'll email you the results when your analysis is finished.
Hypothesis Graveyard
Hypothesis that all pipeline-exclusive peptides are false positives β contradicted by synthetic peptide validations and lower median intensities indicating genuine low-abundance peptides rather than noise.
Hypothesis that rescoring always increases false positives β authors show improvements within 1% FDR and mechanistic feature weight contributions, arguing against wholesale FDR inflation.